1. Sensor operation setup distance: Location (A ) from 0.8mm to 1.2mm, please press setup switch
thereafter 199-0 displayed, move the iron block of the sensor head, it can be adjusted 80~120 as
operation distance.
2. Operation of monitoring value setup: Accuracy range sets up from ±1um~+99um depends on your
exact accuracy requirement.
3. While stamping die starts running, the first four times displaying digits meaning the average of the
die-height testing. (It will be ri-calculated while stamping machine power off or the sensor line out of
the basic unit and re-plug-in )
4. SP: (1) Display it when abnormal speed and machine stop
(2) Display it when upper or lower iron blocks drop out suddenly.
5. OP: Sensor line and Sensor head disconnect or sensor line pull out from the unit.
6. HI: Abnormal too high, the red and yellow light will lights up. (Abnormal red light and
higher yellow light. )
7. LO: Abnormal too low , the red light will lights up. (Abnormal red light and lower red light. )
8. ES: Displays when error carrying, missing material or material jammed.
9. Abnormal light lights up when tolerance displayed value over than pre-set.
10. Self-check functions available.
11. This product provides precision set-up value as 1um, its selectable against different
accurate toolings.
12. Options available for error-carry-on, missing material (By electro-eyes sensor ) and material jammed
(By sensoring bar ).